LOG SENSE Command (4Dh) SDLT 600 SCSI Interface Guide
4-54 January 2005 81-81200-02 REV A01
Figure 4-28. TapeAlert LOG SENSE Page — Parameters Format
Bit
Byte
7 6 5 4 3 2 1 0
0 – 1
(MSB)
Parameter Code
(LSB)
2
1
DU DS TSD ETC TMC LBIN LP
3 Parameter Length (1)
4 Value of TapeAlert Flag (Flag is set when bit 0 is set to 1; bits 1–7 are reserved)
1. The byte 2 fields are collectively referred to as the Parameter Control Byte.
Table 4-32. TapeAlert Page LOG SENSE Parameters — Field Descriptions
Field Name Description
Parameter Code Contains the Flag code. See Table 4-33 on page 4-55 for the
supported flags, level of severity, and the flag definitions.
Parameter Length Always set to 1.
Value of TapeAlert Flag If bit 0 is set to 1, indicates that TapeAlert has sensed a problem. See
Table 4-33 on page 4-55 for the supported flags and their definitions.
If bit 0 is set to 0, indicates that TapeAlert did not sense a problem
and therefore did not set the flag.