8
4.1.5 Having the single-phase motor described at Section 2.3 replaced by a 3-phase
motor.
4.1.6 Having the mechanical totalisers removed from the pullers.
4.1.7 Having submerged or remote hydraulics, in which case the motors and pumping
units are removed from the hydraulic enclosure. However, the meter described at Section 2.2.2
will remain within the enclosure.
4.1.8 Having the grade indication removed.
4.1.9 Having two dispensing units in a satellite configuration, the satellite unit
housing is as described in the Certificate. However, the unit contains no hydraulic components
other than a single stage solenoid valve and retractable hose unit.
4.1.10 Having a dispenser that is capable of delivering at two flow rates. The higher
flow rate is approximately 80L/min and the slow flow rate is approximately 40 L/min.
4.1.11 Having fitted to the dispenser push-buttons that allow the purchaser to preset by
either volume or price a specific delivery amount. There are two buttons that select the
required volume or price. These buttons may have any value and each operation increments the
preset amount by their respective values. A third `CLEAR ALL' button is included which
cancels the total preset amount and allows another to be entered. This button is only
operational up to the point of lifting the nozzle.
4.1.12 Having a volume only display.
4.1.13 Having a separate delivery system fitted for delivering non-fuel products such
as adblue.
4.2 Alternative Enclosure Styles
4.2.1 2000 Range
As described in the Certificate but having the Range 2000 dispenser housing as shown in
Figure 6. The display head is enlarged and mounted on top of heightened hose retraction units,
which are all mounted adjacent to each other. An additional smaller hydraulic housing is
positioned on the opposite side of the hose retraction units in configurations of 4. 6. 8 and 10
hose dispensing units.
4.2.2 Level 5
As described in the Certificate but having the Level 5 dispenser housing as shown in Figure 7.
The display head is mounted on one of the support columns for the hose canopy.
4.2.3 Industrial Cladding
Having the enclosure modified as shown at Figure 8. The cladding may be manufactured of
glass fibre or metal.