ATA Bus Interface and ATA Commands
Quantum Fireball Plus AS 10.2/20.5/30.0/40.0/60.0 GB AT 6-47
6.7.9.6
6.7.9.66.7.9.6
6.7.9.6 SMART EXECUTE OFF-LINE COLLECTION IMMEDIATE
SMART EXECUTE OFF-LINE COLLECTION IMMEDIATESMART EXECUTE OFF-LINE COLLECTION IMMEDIATE
SMART EXECUTE OFF-LINE COLLECTION IMMEDIATE
COMMAND CODE - B0h
PROTOCOL - Non-data command
INPUTS - The Features register shall be set to D4h. The Cylinder Low register shall
be set to 4Fh. The Cylinder High register shall be set to C2h.
ERROR OUTPUTS - If the device does not support this command, if SMART is
disabled or if the values in the Features, Cylinder Low or Cylinder High registers
are invalid, an Aborted command error is posted.
Register
RegisterRegister
Register 7
77
76
66
65
55
54
44
43
33
32
22
21
11
10
00
0
Features D4h
Sector Count na
Sector Number na
Cylinder Low 4Fh
Cylinder High C2h
Device/Head obs ns obs DEV na na na na
Command B0h
Register
RegisterRegister
Register 7
77
76
66
65
55
54
44
43
33
32
22
21
11
10
00
0
Error nananaIDNFnaABRTnana
Sector Count na
Sector Number na
Cylinder Low na
Cylinder High na
Device/Head obs ns obs DEV Head number or LBA
Command BSY DRDY DF na DRQ na na ERR