Configuration for Novell and UNIX Operating System Configuration
52
7. Exit SMIT.
Controlling Data Compression under AIX
After you run SMIT, device files will have been created for your new tape drive. Typical filenames
are listed below:
/dev/rmt0/dev/rmt0.1/dev/rmt0.2/dev/rmt0.3
/dev/rmt0.4/dev/rmt0.5/dev/rmt0.6/dev/rmt0.7
If you enter the configuration information specified in step 5 of the configuration process, devices
rmt0, rmt0.1, rmt0.2 and rmt0.3 will cause the drive to write in compressed mode. Using devices
rmt0.4, rmt0.5, rmt0.6 and rmt0.7 will cause the drive to write with compression disabled.
Configuration for SCO UNIX
Before using the DAT 72 and DDS-4 autoloader in an SCO UNIX environment, set the operating-
system configuration DIP switches as shown below:
Configuration for LINUX
Before using the DAT 72 and DDS-4 autoloader in a LINUX environment, make sure the operating
system configuration DIP switches (switches 5 through 8) are all set to ON.
S5 S6 S7 S8 S10
SCO ON ON ON OFF OFF
UnixWare 7.x ON ON ON ON OFF