Quantum|ATL StackLink™ Installation Instructions
Document 6421009-04, Ver. 4, Rel. 0
February 2002
Cabling the Library 19
Figure 15 Library Control
and StackLink Power
Cabling
3 Connect the bottom M1500 module in the rack to the I
2
C
terminator board:
On a 2-high stack, use library control bus cable PN AS3642.
On a 5-high or 10-high stack, use library control bus cable
PN AS3643.
StackLink Motor
Connection
0
Once you have completed the interlibrary cabling, connect the
StackLink motor cable (PN 214090/01, 214080/01, or 214070/01) from
the StackLink motor to the StackLink motor drive on any of the library
modules (see figure 16
).
Note: The library module that is connected to the StackLink motor
becomes the GUI master.
Library control bus terminator
Library control
bus (daisy
chained)
This cable
completes a loop
back to the I
2
C
terminator board