Quantum Scalar 100 Guide de l'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
16 Installation
Installing the SNC 6101 in a Scalar 100
To install the SNC 6101
1 Power down your Scalar 100 and disconnect the AC power cord from the voltage source.
2 At the rear of the Scalar 100, find the bottom, left filler plate (see Figure 4
).
3 Remove the filler plate by unscrewing the two thumb screws identified in Figure 4
.
4 Position the SNC 6101 module as shown in Figure 5
on page 17. Make certain the two RJ-45 and null
modem ports are positioned at the top.
5 Align the top and bottom rails of the SNC 6101 with those on the Scalar 100 and slide the module into
the chassis until it is flush.
Figure 4 Scalar 100 Filler Plate Removal
CAUTION
Save this filler plates for future use. If the SNC 6101 is removed, the
empty slot must always be covered to prevent debris from entering
the equipment and to enable proper air circulation for cooling.
Note
The mounting rails prevent the SNC 6101 from being inserted wrong side
up.