Chapter 8 Logs and Troubleshooting
Before Contacting Customer Support
Quantum SuperLoader 3 User’s Guide 101
The front panel and light indicators do not turn
on.
Verify that the autoloader is plugged in.
Verify that the power switch on the back is
turned on.
Verify that the drive carrier assembly is locked
into the autoloader chassis with the four
screws supplied.
Contact customer support.
The front panel does not display information, but
light indicators above the front panel are turned
on.
Connect to the autoloader, using On-board
Remote Management with an Ethernet
connection and issue a
System Reset from the
Diagnostics page.
Verify that the drive carrier assembly is locked
into the autoloader chassis with the four
screws supplied.
On the front panel, press and hold the power
switch for 15 seconds, then turn the rear
power switch off. Wait 60 seconds and turn
the rear power switch back on.
Contact customer support.
The autoloader does not communicate with the
host system via the SCSI bus.
Verify that the SCSI cables are connected to
the rear of the autoloader and that the correct
LVD host controller card is installed.
Verify that the SCSI cables are not damaged or
crimped and the total SCSI cable length is not
exceeding the maximum required length.
Verify that a LVD SCSI terminator is attached to
both the first and last SCSI device on the SCSI
bus.
Verify that the autoloader SCSI ID is set to a
unique SCSI ID that is not used by any other
SCSI device on the same SCSI bus.
Issue a
System Reset either by using On-board
Remote Management Diagnostic page or by
turning off power from the front panel.
Contact customer support.