98 Troubleshooting and Help
02 xx
Type 2 Software errors including microcode logic and operating system
errors.
Power off and on the Scalar 100 library to recover from the error. Use the rear
switch to perform this action, wait at least one minute between power off and
on.
03 xx
Type 3 Software errors including microcode logic and operating system
errors.
Power off and on the Scalar 100 library to recover from the error. Use the rear
switch to perform this action, wait at least one minute between power off and
on.
04 xx
Type 4 Software errors (inter processor) including microcode and
operating system errors.
Power off and on the Scalar 100 library to recover from the error. Use the rear
switch to perform this action, wait at least one minute between power off and
on.
05 xx
A permanent operating system error occurred.
Power off and on the Scalar 100 library to recover from the error. Use the rear
switch to perform this action, wait at least one minute between power off and
on.
Contact ATAC.
10 xx
Barcode scanner communications failed.
Retry the failing operation.
Power off and on the Scalar 100 library to recover from the error. Use the rear
switch to perform this action, wait at least one minute between power off and
on.
Contact ATAC.
11 xx
Barcode scanner communication is OK, data received from the barcode
scanner is bad.
Ensure that the barcode label was supplied by ADIC or an ADIC approved
vendor.
Contact ATAC.
Table 8 Service Action Code Descriptions