JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
15-1
15
READ ELEMENT STATUS
(B8h)
15.1 ABOUT THIS COMMAND
The READ ELEMENT STATUS command requests that the library return the
status of its elements. This command returns the data created as a result of the
INITIALIZE ELEMENT STATUS (07h) or INITIALIZE ELEMENT STATUS
WITH RANGE (37h) command. For more information about these commands,
see Chapter 4 and Chapter 5.
Bit
Byte
7 6 5 4 3 2 1 0
00 10111000
01 Reserved VolTag Element Type Code
02 (MSB)
Starting Element Address
(LSB)
03
04 (MSB)
Number of Elements
(LSB)
05
06 Reserved CurData DVCID
07 (MSB)
Allocation Length
(LSB)
08
09
10 Reserved
11
S/N Req
(Obsolete)
Reserved 0 0