Quantum LTO 2U Instructions d'exploitation Page 255

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 264
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 254
JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-23
ERRORS REPORTED OVER THE SCSI BUS
10h 1Ah 00h 5h A 4 Parameter length error. The parameter
list length was not valid. This error is a
result of any of the following:
Parameter List Length error in the
MODE SELECT CDB.
Illegal transfer length in CDB.
10h 20h 00h 5h A 4 Invalid Command OP code. The
operation code (OP code) for the CDB
was invalid.
10h 21h 01h 5h A, O 4 Invalid element address. There was an
invalid element address specified in the
CDB.
10h 24h 00h 5h A 4 Invalid field in CDB. There were invalid
fields in the CDB.
10h 25h 00h 5h A, O 4 Logical Unit not supported. The logical
unit number specified in the Identify
message or in the CDB is not zero.
10h 26h 00h 5h A, O 4 Invalid field in parameter list. There was
an invalid field in the parameter list.
10h 26h 02h 5h A, O 4, 15 Parameter value invalid. There was an
invalid parameter value in the parameter
list.
12h 04h 01h 02h O, B,
A, S
11 Logical Unit becoming ready.The library
is not ready, but is in process of becoming
ready.
12h 04h 12h 02h S, O 8 Library has been placed offline by system.
12h 04h 83h 02h O 11 Not Ready. Door open. The cartridge
access port door is open.
12h 87h 25h 4h I 8, 13, 12 Drive not ready. The tape drive did not
return Ready status after a reset.
Table A-4 REQUEST SENSE error information (FSC, ASC, ASCQ, and SK (continued)
FSC
ASC
(byte 12)
ASCQ
(byte 13)
Sense
Key
Cause ERP SCSI Error Message and Description
Vue de la page 254
1 2 ... 250 251 252 253 254 255 256 257 258 259 260 ... 263 264