JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
7-1
7
LOG SELECT (4Ch)
7.1 ABOUT THIS COMMAND
The LOG SELECT command allows you to reset the statistical information
maintained by the library to zero. The LOG SELECT command does not
transfer any parameters to the library and does not include any parameter
pages.
7.2 WHAT YOU SEND TO THE LIBRARY
Byte 01, Bit 1 – PCR (Parameter Code Reset)
This field specifies whether the library should reset all of the parameters or
only selected parameters, as follows:
Note: If you set the PCR bit to 1, be sure that the Parameter List Length is 0.
Otherwise, the library will return Check Condition status with the sense
key set to Illegal Request (5h), the ASC and ASCQ set to 24h and 00h.
Bit
Byte
7 6 5 4 3 2 1 0
00 01001100
01 Reserved PCR SP
02
Reserved
08
09 00 Reserved 00
0 Do not reset any parameters
1 Reset all of the parameters