Quantum SuperLoader 3 Guide de l'utilisateur Page 125

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 160
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 124
Chapter 2 Media Changer Commands
Read Element Status Command (B8h)
Quantum SuperLoader 3 Software Interface Guide 109
Table 51 Import / Export
Element Descriptor
6-8
Reserved
9
SVALID Invert Reserved
10-11
Source Storage Element Address
•••
(36 bytes)
Primary Volume Tag Information
(filed omitted if PVOLTAG=0)
•••
(1 byte)
Reserved Code Set
(1 byte)
Reserved Identifier Type
(1 byte)
Reserved
(1 byte)
Identifier Length
Field Name Description
INENAB This field is sent as 1 to indicate that the import/
export element supports movement of media into the
scope of the media changer device.
EXENAB This field is sent as 1 to indicate that the import/
export element supports movement of media out of
the scope of the media changer.
Access When set to 1 it indicates that access to the element by
a medium transport is allowed. When set to 0 it
indicates that access is denied. This may occur if the
user is performing an operation from the front panel
or Ethernet connection that prohibits access from
SCSI.
Bit
Byte 7 6 5 4 3 2 1 0
Vue de la page 124