Chapter 2 Media Changer Commands
Log Sense Command (4Dh)
Quantum SuperLoader 3 Software Interface Guide 40
Table 18 Device Status Log
Sense (0001h)
Field Name Description
Temperature These two bits indicate the temperature of the device. This field follows the
following format:
Bit 3 Bit 2 Description
0 0 Not supported
01OK
1 0 Warning: Safe temperature exceeded.
1 1 Maximum temperature exceeded.
Status These two bits indicate the overall condition of the device. The status of the
device follows the following format:
Bit 1 Bit 0 Description
0 0 Not supported
01OK
10Degraded
1 1 Failed