Chapter 6 Running the Demonstration Programs
Running the Demo 3 Program
ATL M-Series User’s Guide 101
Running the Demo 3 Program 6
The
Demo 3 program causes the robot to pick a cartridge from a
randomly selected occupied magazine slot and place it back in the
same slot. The robot then moves to another randomly selected
occupied slot and repeats the process.
To run the
Demo 3 program:
1 Verify that at least one magazine is installed in the library and
that at least one cartridge is present.
2 Access the Demo Programs screen (see Accessing the Demo
Programs Screen).
3 Press the Up or Down buttons to select Demo 3.
4 Press Select.
The
Demo 3 program starts. This program continues until you
press the
Stop button.
5 If desired, include the drives or the fixed slot in the test:
a If the library is an ATL M1500 in a multiple library stack or
an ATL M2500, press the
Level button to select the level
where the desired drive or fixed slot is located.
b Press Drive 1 or Drive 2 to include a drive.
c Press Fixed to include the fixed slot.
6 To stop the program, press Stop.
The GUI displays a status screen listing the demonstration
program number, the number of cycles completed, and the
status of the test: pass or fail.
7 Press Back to return to the Demo Programs screen.