Chapter 3 Changing the Library Configuration
Changing the Emulation Setting
ATL M-Series User’s Guide 59
Changing the Emulation Setting 3
The
Emulation option allows you to set the library to act as either a
Quantum ATL library or an M4 Data library.
To set the emulation:
1 Access the Configuration screen (see Accessing the
Configuration Screen on page 53).
2 Press the Up or Down buttons until Emulation is highlighted.
3 Press Select.
4 Use the Up or Down buttons to select the desired Emulation
setting. The available settings are
ATL M2500, ATL 1500, and
M4 Data.
5 Press Select.
To return to the
Configuration screen without changing the
option setting, press
Cancel.
6 Press Main to return to the main screen.
Note: The default setting for the ATL M1500 is M4 Data; the
default setting for the ATL M2500 is
ATL M2500.
Caution: If you do not return to the main screen after
changing this setting, your change will not be
saved to NVRAM.
Note: You must reboot the library before this setting will
take effect.