Appendix B Fault Symptom Code (FSC) Dictionary
126 ATL M-Series User’s Guide
2504 FSC_SCSI_INVALID_
PAGE_CODE
Bad page code in send
diagnostic
Host 100%
2600 FSC_SERVO_NO_
RESOURCE
SERVO task
initialization failed
Microcode 100%
2601 FSC_SERVO_QUEUE_
FULL
SERVO queue full Microcode 100%
2602 FSC_SERVO_X_AXIS_
NOT_IN_POSITION
The X axis failed to get
to its target position
2603 FSC_SERVO_Y_AXIS_
NOT_IN_POSITION
The Y axis failed to get
to its target position
2604 FSC_SERVO_THETA_
AXIS_NOT_IN_
POSITION
The THETA axis failed
to get to its target
position
2605 FSC_SERVO_PICKER_
AXIS_NOT_IN_
POSITION
The PICKER axis failed
to get to its target
position
2606 FSC_SERVO_SHUTTLE_
AXIS_NOT_IN_
POSITION
The Shuttle axis failed
to get to its target
position
2607 FSC_SERVO_Z_AXIS_
NOT_IN_POSITION
The Z axis failed to get
to its target position
2608 FSC_SERVO_X_TACHO_
COUNTER_FAILURE
The X axis tacho
counter failed to clear
at power-on
System PWA 100%
2609 FSC_SERVO_Y_TACHO_
COUNTER_FAILURE
The Y axis tacho
counter failed to clear
at power-on
System PWA 100%
260A FSC_SERVO_THETA_
TACHO_COUNTER_
FAILURE
The Theta axis tacho
counter failed to clear
at power-on
Hand PWA
System PWA
80%
20%
FSC Name Description FRU Name Confidence %