Chapter 6: Getting Information About the Library
Viewing the All Slots Report
Quantum Scalar i40 and Scalar i80 User’s Guide 147
Viewing the All Slots Report
The All Slots report contains information on all storage, import/export (I/
E) station, and tape drive slots that are currently assigned to one or
more partitions.
The report contains the following information about each slot:
Slot Type — I/E station, storage, cleaning, or tape drive slot.
Barcode — Barcode number of the cartridge installed in the slot. No
barcode number means the slot is empty. “No_Label” means the
barcode is unreadable.
Partition — Partition that owns the slot (I/E station slots are shared
by all partitions).
Location — Location coordinates of the slot.
Element Address — Element address of the slot.
Get Count — The number of times the picker successfully removed
a tape from the slot.
Get Retries — The number of times the picker had to perform a
recovery operation to remove a tape from the slot.
Put Count — The number of times the picker successfully placed a
tape into the slot.
Put Retries — The number of times the picker had to perform a
recovery operation to place a tape into the slot.
Web Client
Select Reports > All Slots.