Quantum DLT 4000 Manuel Page 247

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 300
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 246
SCSI Commands
Quantum DLT 4000 Tape Drive 5-147
5.22 SEND DIAGNOSTIC COMMAND (1DH)
The SEND DIAGNOSTIC command directs the tape drive to perform its self-
diagnostic tests.
Bit
Byte
7 6 5 4 3 2 1 0
0 Operation Code (1Dh)
1 Logical Unit Number PF (0) Rsvd Selftst DevOfl UnitOfl
2 - 4 Reserved
5 Unused Reserved Flag Link
Figure 5–73 SEND DIAGNOSTIC Command Descriptor Block - Data Format
Table 5–71 SEND DIAGNOSTIC Command Data - Field Descriptions
Field Name Description
PF Page Format. Not supported; must be 0.
Selftst Self Test. This bit is used in conjunction with DevOfl and UnitOfl to specify the
type of testing to be done. An explanation is provided in the following
paragraphs.
DevOfl Device Offline. This bit is used in conjunction with Selftst and UnitOfl to specify
the type of testing to be done. An explanation is provided in the following
paragraphs.
UnitOfl Unit Offline. This bit is used in conjunction with Selftst and DevOfl to specify
the type of testing to be done. An explanation is provided in the following
paragraphs.