SCSI Commands
Quantum DLT 7000 Tape System 5-73
MODE SELECT (6) / (10) Command (15h) / (55h) (continued)
Table 5–39 MODE SELECT Page Descriptor - Field Descriptions
Field Name Description
PS Parameters Savable. For the MODE SELECT (6) (10) commands, this field
is reserved (0).
Additional Page Length Indicates number of bytes in that page (not including bytes 0 and 1).
Page-Defined or Vendor
Unique Parameter List
Information in this field depends on the mode page. Refer to Sections
5.9.2 through 5.9.9.
5.9.2 READ / WRITE Error Recovery Page (01h)
The READ / WRITE Error Recovery Page controls the drive’s response to error
conditions that arise during the course of READ and WRITE command
processing.
Bit
Byte
7 6 5 4 3 2 1 0
0
PS (0) 0
Page Code (01h)
1 Additional Page Length (0Ah)
2 Rsv’d Rsv’d TB Rsv’d EER (1) PER DTE (0) DCR (0)
3 Read Retry Count
4 – 7 Reserved
8 Write Retry Count
9 – 11 Reserved
Figure 5–37 Error Recovery Page - Data Format