SCSI Commands
Quantum DLT 7000 Tape System 5-133
5.14 READ BUFFER COMMAND (3Ch)
The READ BUFFER command is used in conjunction with WRITE BUFFER as a
diagnostic function for testing the drive’s data buffer for possible diagnostic data
and for checking the integrity of the SCSI bus. In addition, by using buffers 1
and 2, the READ BUFFER command allows the contents of the tape system’s
local RAM/EEPROM, and DRAM to be transferred over the SCSI bus. Buffers 1
and 2 provide a diagnostic capability for the system’s firmware.
Bit
Byte
7 6 5 4 3 2 1 0
0 Operation Code (3Ch)
1 Logical Unit Number Reserved Mode
2 Buffer ID
3 - 5
(MSB)
Buffer Offset
(LSB)
6 - 8
(MSB)
Allocation Length
(LSB)
9 Unused Reserved Flag Link
Figure 5–64 READ BUFFER Command Descriptor Block - Data Format