General Description and Specifications
Quantum DLT 8000 Tape System 1-11
1.3.12 Power Requirements
Table 110 provides the applicable power requirements for both versions of the tape
system. Note that the tabletop version requires ac power.
Table 110 Power Requirements
Description Integratible Version Tabletop Version
Electrical Rating (Auto
Ranging)
Not applicable 100 to 240 VAC
Power Requirements 28 W, steady state 56 W, maximum
Power Consumption:
+5 V (±5%) bus *
+12 V (±5%) bus *
2.8 A, steady state;
4.35 A, maximum
1.2 A, steady state;
4.5 A, maximum
Not Applicable
Not Applicable
* = Voltage measured at the power bus connector pins.