60 SCSI Commands
Position to Element – 2Bh
What the Library Does With This Command
The library will move the picker in front of the specified element at the current media Get position.
Command Usage
This command can be used to pre-position the robotics to an element to enhance performance, or it can be
used as a general-purpose way to relocate the robotics without involving media movement. This might be
useful for diagnostic or demonstration purposes.
Position to Element CDB Format
The POSITION TO ELEMENT CDB format is shown in the following table.
Medium Transport Element Address – This field contains the address of the Medium Transport element
to position. A value of 0001h is the address of the Medium Transport element, but a value of 0000h is also
supported (which selects the default Medium Transport element).
Destination Element Address – This field contains the element address of the target to position to. It can
be a storage, data transfer, or import/export element.
Invert – This field must be set to 0.
Table 57 POSITION TO ELEMENT CDB format
Bit
Byte
76543210
0Op Code (2Bh)
1 Logical Unit Number Reserved
2
Medium Transport Element Address
3
4
Destination Element Address
5
6
Reserved
7
8 Reserved Invert
9 Control