Quantum Scalar i80 Guide de l'utilisateur Page 254

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 404
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 253
Chapter 9: Installing, Removing, and Replacing Components
Taking ESD Precautions
226 Quantum Scalar i40 and Scalar i80 User’s Guide
Removing and Replacing a Magazine
Removing and Installing a Power Supply
Removing and Replacing the System Control Board
Removing and Replacing a Tape Drive
Packaging the Library for Moving or Shipping
Replacing the Y-tray with Robot
Taking ESD Precautions
Some components within the Scalar i40 and Scalar i80 libraries contain
static-sensitive parts. To avoid damaging these parts while performing
installation procedures, always observe the following precautions:
Use an antistatic wrist strap. If you do not have one, touch the
ou
tside of the library on the sheet metal before touching any
components to discharge static from your body.
Keep static-sensitive parts in their original shipping containers until
ready for installation. Look
for the ESD sticker to identify static
sensitive parts.
Avoid touching connectors and other components.
Note: Dry climates and cold-weather heating environments have
lower relative humidity and are more likely to produce static
electricity.