Quantum Scalar 50 LTO-3HH Guide de l'utilisateur Page 165

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 290
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 164
Chapter 4 SNMP Trap List
Quantum Scalar 50 User’s Guide 141
XY-cal offset fail The calibration test used to
compute offsets for the robotics
tray has failed.
Critical Diagnostics
Z & hand cal offset fail The calibration test used to
compute offsets for the robotics
tray up/down and robotics hand
has failed.
Critical Diagnostics
Z & hand_theta cal offset
fail
The calibration test used to
compute offsets for the robotics
tray up/down and robotics hand
rotation has failed.
Critical Diagnostics
Z & hand_trans cal offset
fail
The calibration test used to
compute offsets for the robotics
tray up/down and robotics hand
translation has failed.
Critical Diagnostics
Z-cal offset fail The calibration test used to
compute offsets for the robotics
tray up/down has failed
Critical Diagnostics
Hand-trans axis init fail The robotic hand could not
initialize the translation axis.
Critical Diagnostics
Hand-trans home fail The robotic hand could not home
the translation axis.
Critical Diagnostics
Hand-trans motor fail
(zone #)
The robotic hand has failed to
position translation to a
predetermined physical location.
Critical Diagnostics
Hand-theta axis fail
(zone #)
The robotic hand has failed to
position rotation to a
predetermined physical location.
Critical Diagnostics
Hand-theta axis init fail The robotic hand could not
initialize the rotation axis.
Critical Diagnostics
Hand-theta home fail The robotic hand could not home
the rotation axis.
Critical Diagnostics
Event Detail Event Description Category Reported By
Vue de la page 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 289 290

Commentaires sur ces manuels

Pas de commentaire