Operating The AML/2 System
Page 5 - 32 Operator Guide 1097 DOC B00 001
5.9 Start “MANUAL”
In this operating mode the drive amplifiers of the robots are voltageless.
This operating mode is intended exclusively for:
input and output of media
manual operation of drives
automatic movement of Quadro towers.
WARNING!
Movements of system components inside the archive can cause severe injury.
Before starting the system ensure that nobody is inside the archive.
The AML/2 system must be operated exclusively by trained personnel that is regi-
stered in the system logbook.
a) Set the operating mode selector switch to “MANUAL”, remove the key and
keep it in a place unaccessible for unauthorized persons.
b) Switch the main switch on.
<CONTROL OFF> lights up yellow.
c) Press <SYSTEM ON>.
<SYSTEM ON> lights up green: EMERGENCY STOP circuit is activated.
d) Press <CONTROL ON>.
<CONTROL OFF> remains on, <CONTROL ON> lights up green.
The drive amplifiers for the Quadro towers are switched on.
The Quadro towers can be addressed via the AMU (Manual Operation) opera-
ting panel.
5.10 Changing the Operating Mode
a) Select 6KXW GRZQ$%%$
b) Press <CONTROL OFF>.
<CONTROL ON> switches off, <CONTROL OFF> lights up yellow.
c) Change the operating mode.
d) Press <CONTROL ON>.
e) Restart AMU: enter „startup“ in an OS/2 window.
!