12-94 6-00667-01 Rev B
Scalar 100
A0 xx
Communication is not established between the Main Controller PCBA and
the auxiliary controller PCBA’s in the library.
Contact ATAC.
A1 xx
Communication was established but has been lost between the Main
Controller PCBA and the auxiliary controller PCBA’s in the library.
Contact ATAC.
A2 xx
Communication was initially established but is now lost between the Main
Controller PCBA and the Picker Control PCBA.
Contact ATAC.
A3 xx
Communication was initially established but is not lost between the Main
Controller PCBA and the Display Control PCBA.
Contact ATAC.
D2 xx
The Library detected that a fan has failed in one of the DC Power Supplies.
If this Library has only one DC Power Supply, replace the DC Power Supply.
If this Library has two DC Power Supplies, listen to the fan located on the back
of each Power Supply. Replace the Power Supply that does not have the fan
running.
E0 xx
A cartridge is stuck in the Picker Assembly, Operator Intervention is
required to remove the cartridge from the Grip fingers.
Remove the cartridge.
E1 xx
The mailbox door is not fully closed.
Close the mailbox door
E2 xx
The front door is not fully closed, Operator Intervention is required to
close the door.
Close the front door.