Troubleshooting and Help 12-89
Scalar 100
14 xx
The system detects that the Serial Number is missing from its NVRAM.
Record and reenter the System Serial Number (Using serial cable and
HyperTerminal. Enter “setser” command from the HyperTerminal prompt.
Contact ATAC.
15 xx
An intermittent scanning error was detected. During Demo, the library
performs inventory after each complete demo cycle and detects a
mismatch between the number of cartridges scanned and its previous
database.
Note the number of cartridges installed in the library and use the Operator Panel
to compare this information with the number of cartridges reported by the
library. Examine the cartridges that are installed but not reported by the library
for proper cartridge labels, replace the labels if necessary. Note that if a whole
column of cartridges is missing, the column fiducial label can be defective, in
this case the whole storage column must be replaced.
If all labels are correct, clear the SAC and retry the Demo program (at least five
cycles).
Contact ATAC.
21 xx
NVRAM failures.
Check the Library configuration and re-enter all data (SCSI ID, Time/Date,
Library Serial Number, etc.). For instructions on how to do this, see
Configuring your Library on page 8-57
.
Power Off and On the Scalar 100 Library a few times and see if the same error
conditions re-appear. Use the Rear Switch to perform this action, wait at least
one minute between power Off and On.
Contact ATAC.
38 xx
The Remote Management Unit (RMU) can not communicate with the DHCP
server.
Contact ATAC.
39 xx
An external network error was detected by the Remote Management Unit
(RMU).
Ensure that the network cable is connected from the DHCP server to the RMU.
Ensure that the RMU is configured to operate with the DHCP.
Contact ATAC.
40 xx
The Library detects that Servo power is missing.
Contact ATAC.
Reported
SAC
Error and Solution