Quantum Scalar 10K Instructions d'exploitation Page 166

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 324
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 165
4-88 Menus and Commands
6-00058-05 Rev A
ID Dialog
Path: Main Menu Setup Drives ID
Use the ID Dialog to change a SCSI/loop ID of a new or
current drive. See Figure 4-125.
Note: If you change any settings, you must Vary Off and Vary
On the drive to apply the new settings.
Figure 4-125 SCSI Drive Selection
Parameters Description
Coord The first field indicates the
type of cell, D for Drive
The second field indicates the
rack number (01–16)
The third field indicates the
drive section (1–4)
The fourth field indicates the
column of the section (A or B)
The fifth field indicates the
row of the column (01–06)
Index The device address associated
with the selected coordinate
parameter. DT = data transfer
device.
Accept Y to accept
N to reject
If Y is selected, the Drive Parameters appear. See
Figure 4-126.
Figure 4-126 Drive Parameters (Fibre Drive Example)
Enter SOURCE
Coord: D 08< 4 B 01
Index: DT 00038
Accept:N
Drive: DT 00001<
[08-1-A-01]
ID: 001 New ID: 001
Port : 1 Accept: N