6-26 Error Messages
6-00058-05 Rev A
7A 00 00 Failures detected in the Gripper Assembly Retract operations.
Action 1
Contact GCH. For GCH contact information, refer to Getting More Information
or Help on page 1-8.
7B 00 00 Failure detected in a Teach Master operation. This failure occurs most
likely when a Teach operation is executed as part of the Installation
process.
Action 1
Contact GCH. For GCH contact information, refer to Getting More Information
or Help on page 1-8.
7C 00 00 Failures detected in the Gripper Assembly Reach operation.
Action 1
Check for an object blocking operation in the cell. An obstruction can be any
of the following:
an unlabeled cartridge
a cartridge in the cell during a Put operation
the DLT drive door is stuck during a Put operation
Remove the obstruction, then close the aisle door and retry the failing
operation.
Action 2
If the problem is not corrected or persists, contact GCH. For GCH contact
information, refer to Getting More Information or Help on page 1-8.
7E 00 00 Failure detected while pushing a cartridge into a tape drive feed slot.
Action 1
Check the cartridge for any physical damage, and verify that the cartridge
label is correct.
Action 2
Check the front of the drive sled to make sure no physical obstructions are
preventing the tape from being inserted.
Action 3
If the problem is not corrected or persists, contact GCH. For GCH contact
information, refer to Getting More Information or Help on page 1-8.
Table 6-2 Service Action Codes (Continued)
Reported
SAC
Perform these actions