Quantum Scalar 10K Instructions d'exploitation Page 304

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 324
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 303
6-30 Error Messages
6-00058-05 Rev A
94 xx yy Communication was established between the Library and the tape drive
but the Library cannot determine the status of a particular Tape drive.
Action 1
Use the modifier xx yy to locate the failing tape drive:
xx = rack number (1 to 16)
yy = drive location (1 to 48)
Where 1 is the bottom right drive location (viewing from the back of the
module) and 48 being the top left drive location. Drives are counted from
right to left and bottom to top. Refer to Service Action Codes on page 6-11 for
more information on SAC modifiers.
Action 2
Do the following to power cycle the drive:
1. Vary Off the drive (Main Menu Utils Drives Status Change Vary
Off).
2. Reseat the drive. Wait for the following green LED blink pattern: Blink,
blink, blink, pause.
3. Vary on the drive (Main Menu Utils Drives Status Change Vary
On).
4. Retry the operation that failed.
Action 3
If the problem is not corrected or persists, contact GCH. For GCH contact
information, refer to Getting More Information or Help on page 1-8.
Table 6-2 Service Action Codes (Continued)
Reported
SAC
Perform these actions
Vue de la page 303
1 2 ... 299 300 301 302 303 304 305 306 307 308 309 ... 323 324

Commentaires sur ces manuels

Pas de commentaire