Service Menu 4-151
September 2007
Self Test Dialog
Path: Main Menu Service Diags Self Test
Use the Self Test Dialog to run a predetermined sequence of
diagnostics and exercisers. See Figure 4-234.
Figure 4-234 Self \Test Dialog
Parameters Description
Cycles to Run Indicates the desired cycle
count (001–999)
Accept Y to accept changes
N to reject changes
If Y is selected, the Response Dialog appears. See
Figure 4-235. Otherwise, the changed parameters
continue to display but no action is taken.
Figure 4-235 Response Dialog
Parameters Description
Cycle The number of completed test
cycles of the requested cycles
Status Shows the status of the
indicated cycle (Running,
Completed, Error, Canceled)
Cancel Y to cancel the test
N to continue running the test
If Y is selected for the Cancel parameter value, the test is
canceled. Otherwise, the test continues.
The self test runs
a sequence of diags.
Cycles to run:009<
Accept: N
DIAGS SELF TEST
Cycle :006 of 009
Status:Running
Cancel: N<
Note
If the operation
stops, the Cancel
parameter no
longer displays.