Chapter 3 Operator Commands
Configuring Library Options
ATL P2000 Series Automated Tape Library Users Guide 49
3
Press the Select button until you highlight the setting you want
to change.
4
Using the arrow buttons, scroll through available values for the
setting.
5
Press the Change button to accept the new value.
6
Repeat steps 3 through 5 to make other changes.
7
Press the Back button to return to the Configure: Library
screen.
The options you selected are now part of the library configuration.
SCSI ID
Assignment
Guidelines
3
When selectingSCSI ID numbers, each SCSI device on the same
bus must have a unique number from 0 to 15. SCSI devices include
the library robotics, the host computer, the library tape drives,
internal and external hard disk drives, and so on.
If you set up the library with multiple SCSI buses, you can assign
the same number to two or more devices, provided each device is
on a different SCSI bus.
Configuring Library Options
3
The Configure Options command allows you to set the following:
Power-On Statedetermines whether the library is on-line or in
standby mode when powered up. The default setting is On-
line.
AutoCleanallows the library to perform drive cleaning tasks
automatically as needed. The default setting is Disabled.
Note:
Power must be cycled for the new SCSI ID number to
become effective.