Scalar 24 Installation and Operation Guide 87
Selection Description/Result
1 From the Setup menu, highlight and
press to get to the Net Device menu.
2 Press and to change the value of
the current field from RMU to iSCSI. Press
to highlight Execute ( ) when the
value is correct. Press .
Available options are:
•RMU
iSCSI
An error appears if the hardware is not
installed or is not functioning properly.
3 Set the IP Address by pressing and
to change the value of the current field and
and to move between fields.
The current field is highlighted. Make sure you
enter a valid number for each field.
4 Set the Subnet mask by pressing and
to change the value of the current field
and and to move between fields.
The current field is highlighted. Make sure you
enter a valid number for each field.
5 Set the Gateway by pressing and to
change the value of the current field and
and to move between fields.
The current field is highlighted. Make sure you
enter a valid number for each field.
6 From the last field of the Gateway address,
press to set the Gateway mask and
highlight Execute ( ).