SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-77
Table 4-47. Read / Write Error Recovery MODE SELECT Page — Field Descriptions
Field Name Description
PS Parameters Savable. For MODE SELECT, must be set to 0.
Page Code Identifies the type of MODE SELECT page being transferred. A
value of 01h identifies this as the Read / Write Error Recovery
Page.
Page Length Indicates the number bytes in the page, excluding bytes 0 and 1.
The length is returned in MODE SENSE commands and must
subsequently be set to the same value when performing MODE
SELECT. If the drive receives an unexpected page length value, it
returns a CHECK CONDITION status, Sense Key set to
ILLEGAL REQUEST.
TB Transfer Block. Not supported.
EER Enable Early Recovery. Must be set to 1.
PER Post Error. Default is 0. When set to 1, enables reporting of
CHECK CONDITION to report recovered READ / WRITE errors.
DTE Disable Transfer on Error. Not supported. Must be set to 0.
DCR Disable ECC Correction. Not supported. Must be set to 0.
Read Retry Count This field reports the maximum number of read retries the drive
attempts before reporting an unrecoverable error.
Write Retry Count This field reports the maximum number of write retries the drive
attempts before reporting an unrecoverable error.