INQUIRY Command (12h) SDLT 600 SCSI Interface Guide
4-22 January 2005 81-81200-02 REV A01
Vendor-unique Logical Unit Identifier
Figure 4-8 shows the format of the Vendor-unique Logical Unit Identifier.
Figure 4-8. Vendor-unique Logical Unit Identifier— Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 Protocol Identifier Code Set (2h)
1 PIV (0) Rsv’d Association (0) Identifier Type (1)
2 Reserved
3 Identifier Length
4 – 11
(MSB)
Vendor Identification
(LSB)
12 – 27
(MSB)
Product Identification
(LSB)
28 – n
(MSB)
Serial Number
(LSB)
Table 4-12. Vendor-unique Logical Unit Identifier — Field Descriptions
Field Name Description
Protocol
Identifier
Set to 0.
Code Set Indicates the type of data found in the Identifier field. Set to 2h, indicating
ASCII graphic code (values 20h through 7Eh) data.
PIV Protocol Identifier Valid. Set to 0, indicating that the value returned in the
Protocol Identifier field should be ignored.
Association Set to 0, indicating that the Identifier is associated with the logical unit.
Identifier Type Type of identifier.
Value Description
1h T10 vendor identification