Quantum 1200 Series DAT Autochanger Guide de l'utilisateur Page 176

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 294
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 175
MODE SENSE (6) / (10) Command (1Ah / 5Ah) SDLT 600 SCSI Interface Guide
4-134 January 2005 81-81200-02 REV A01
EEPROM Vendor Specific Page (3Eh)
This page returns all of the EEPROM parameters that can be set with the MODE SELECT EEPROM
Vendor Specific page; it sometimes returns an error message in the returned ASCII string.
The 10-byte MODE SENSE command for the EEPROM page returns data in the form of a MODE
SENSE (10) data header followed by block and page descriptors.
Figure 4-75. EEPROM Vendor Specific MODE SENSE Page — Data Format
As with other MODE SENSE pages, the data in the page descriptor is organized in the form of a
parameter header followed by the parameters value. The parameter is as follows:
Name T Current Default Minimum Maximum
Table 4-76 lists the parameter definitions:
TECH TIP: The length of the list of EEPROM parameters requires a 10-byte
MODE SENSE command. If you use a 6-byte MODE SENSE
command to retrieve the EEPROM parameters, you will receive
the following response:
Send a 10-byte MODE SENSE command to get the
Parameter List.
Bit
Byte
7 6 5 4 3 2 1 0
0 PS (0) Rsv’d Page Code (3Eh)
1 Page Length
2 - n ASCII String of Parameter Name or Value
Table 4-76. EEPROM Vendor Specific MODE SENSE Page — Field Descriptions
Field Name Description
Name Refers to the parameter name, for example, ProductID or DefaultCompOn.
T Type. Designates data type; “b” indicates binary, “A” indicates string type, no
designator indicates that the data is in decimal format.
Current,
Default,
Minimum, and
Maximum
Specifies the current, default, minimum, and maximum values of the parameter.
Vue de la page 175
1 2 ... 171 172 173 174 175 176 177 178 179 180 181 ... 293 294