MODE SELECT (6) / (10) Command (15h / 55h) SDLT 600 SCSI Interface Guide
4-98 January 2005 81-81200-02 REV A01
4.9.13 EEPROM Vendor Specific Page (3Eh)
The drive supports an EEPROM Vendor Specific Page that enables an initiator to modify savable
parameters. Only one savable parameter can be changed per MODE SELECT command.
Figure 4-56. EEPROM Vendor Specific MODE SELECT Page — Data Format
The ASCII string has a parameter name followed by one or more space characters, a parameter value,
and an ASCII line feed or null character. When the string is parsed, the parameter value is interpreted
as shown in the following table. Note that the parameter name may be in upper or lower case. The
drive saves the savable parameters during resets and power cycles.
Bit
Byte
7 6 5 4 3 2 1 0
0 PS Rsv’d Page Code (3Eh)
1 Page Length
2 - n ASCII String of Parameter Name and Value
Table 4-58. EEPROM Vendor Specific MODE SELECT Page — Parameter Descriptions
Parameter Name
Data
Type
Default
Length
(Bytes)
Usage
VendorID ASCII QUANTUM 8 Vendor Identification field in
INQUIRY data.
ProductID ASCII SDLT600 16 Product Identification field in
INQUIRY data. SDLT600 for the
SDLT 600 tape drive.
BTHDirMode Decimal 2 1 Obsolete.
CacheTMs Binary 0 1 When set, the drive always treats a
WRITE FILEMARKS command
that writes a single filemark and is
not preceded by another WRITE
FILEMARKS command as if the
Immed bit was set to 1.
DefaultCompON Binary 1 1 When set to 0, indicates that
compression is defaulted OFF at
power-on/reset.
When set to 1, indicates that
compression is defaulted ON at
power-on/reset.
DefFixedBlkLen Decimal 0 4 Default fixed block size.