SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-105
4.9.14 Changeable Parameters Within MODE SELECT
The following table lists the MODE SELECT command’s changeable parameters and their default,
minimum, and maximum values. Descriptions of the various parameters are provided in the
discussions of the different MODE SELECT mode pages.
NOTE: Parameter rounding is supported for all parameters except the Block
Descriptor Length parameter.
Table 4-59. Changeable Mode Parameters Within MODE SELECT
Page: Parameter Default Minimum Maximum
Header: Buffered Mode, Device Specific Byte 1 0 1
Block Descriptor Length 08h 00h 08h
Block Descriptor: Block Length 0 0
FFFFFCh
1
Read / Write Error Recovery (01h): PER bit 0 0 1
Control Mode (0Ah): Report Log Exception
Condition
00 1
Control Mode (0Ah): Autoload Mode 0 0 2
Data Compression (0Fh): Data Compression Enable 1 0 1
Disconnect / Reconnect (02h): Maximum Burst Size 0080h 0000h FFFFh
Disconnect / Reconnect (02h): DTDC 0 0 3
Device Configuration (10h): Write Delay Time 64h 64h 1964h
Device Configuration (10h): Synchronize at Early
Warning
10 1
Device Configuration (10h): Select Data Compression
Algorithm
10 1
TapeAlert (1Ch): DExcpt 1 0 1
TapeAlert (1Ch): Perf 0 0 1
TapeAlert (1Ch): Test 0 0 1
TapeAlert (1Ch): MRIE 3 0 6
TapeAlert (1Ch): Test Flag 0 0
Vendor Specific Configuration (25h): Default Density
Override
00 FFh