SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-49
4.8.5 Sequential Access Device Log Page (0Ch)
This page provides a standardized way to report the amount of data transferred between the tape drive
and the host.
Figure 4-23. Sequential Access Device LOG SENSE Page — Header Format
Figure 4-24. Log Parameters Format for Sequential Access Device LOG SENSE Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Page Code (0Ch)
1 Reserved
2 – 3
(MSB)
Page Length
(LSB)
Table 4-27. Sequential Access Device LOG SENSE Header — Field Descriptions
Field Name Description
Page Code Echoes the page code specified in the LOG SENSE CDB.
Page Length Specifies the total number of bytes contained in this log page, excluding
the 4 bytes that make up the header.
Bit
Byte
7 6 5 4 3 2 1 0
0 – 1
(MSB)
Parameter Code
(LSB)
2
1
DU DS TSD ETC TMC Rsv’d LP
3 Parameter Length
4 – 11 Parameter Value
1. The byte 2 fields are collectively referred to as the Parameter Control Byte.