Chapter 3 Configuring Your Library
Configuring Library Security Settings
Scalar i500 User’s Guide 124
The paths to open the appropriate screens are as follows:
From the Web client, select
Setup > I/O Blades > Data Path
Conditioning
.
From the operator panel, select
Setup > I/O Blades > Data Path
Conditioning
.
Configuring Library Security Settings
Administrators can use the operator panel Security Settings screen to
change the following security features:
Network Interface — Enables external access to the library over
Ethernet. This setting is enabled by default to allow external access.
SSH Services — Opens port 22 to allow Secure Shell (SSH) services,
to access the library. This setting is enabled by default.
ICMP — Enables external attempts to discover the library by pinging
it (by means of the Internet Control Message Protocol [ICMP] Echo
packets). This setting is enabled by default.
Remote UI —Opens port 80 to allow remote access to the library via
the Web client. This setting is enabled by default.
SNMP — Opens port 161 to allow SNMP communication to the
library. This setting is enabled by default.
SMI-S — Opens port 5988 to allow SMI-S communication to the
library. This setting is enabled by default.
Note: This setting differs from enabling SNMP services in the
Tools > System Settings menu (see Enable SNMP V1/V2
on page 129). In order to run SNMP, the port must be open
and the SNMP services must be enabled.