Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack
Scalar i500 User’s Guide 417
12 Check the status of the power supply’s LEDs. The top green LED and
the blue LED should be solidly lit.
13 Power on the library.
14 Check the status of the power supply’s LEDs. The two green LEDs
should be solidly lit, and the blue LED should be off.
Installing the Library in a Rack
All Scalar i500 libraries taller than 14U must be installed in a rack. The
rack secures the bottom module, and all other modules are then secured
to the bottom module.
The rackmount kit secures your library within a rack. These instructions
explain how to install your stand-alone library into a rack and how to
install additional modules into an existing rack.
Installing the modules into the rack requires at least two people.
Warning: All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm
2
(14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.
Warning: Under no circumstances should a rack be moved while
loaded with one or more modules.