Unless the situation requires it, uses the host
application to move, load, unload, import, or
export cartridges instead of doing so through the
LMC. Using the host to move media makes sure
that the host’s view of the library remains in sync
with the library’s actual configuration.
Chapter 7 Working With Cartridges and Barcodes
Managing Media
Scalar i6000 User’s Guide 511
Importing Cartridges Into
Partitions 7
When you first start using your library, open the door and manually
insert, directly into storage slots, as many cartridges as you plan to use.
The cartridges will not go back all the way if they are inserted incorrectly.
After your library begins operation, use the Import Me
dia dialog box to
add cartridges without interrupting library operations. Place cartridges in
the I/E station. The scanner automatically reads the barcodes on new
cartridges.
1 Ma
ke sure that you are viewing the partition into which you want to
import a data cartridge. From the View menu, click the name of the
appropriate partition.
2 Inse
rt a data cartridge into an appropriate I/E station. You can insert
multiple cartridges up to the maximum number of slots in your I/E
station.
3 To see
which I/E stations are associated with a particular partition,
click Monitor > IE Station.
4 Click Operations > Import
or click the Import toolbar button.
If the partition is not off
line, you receive a message that asks you
whether you want to take it offline.
5 Click Yes.