Chapter 3 Troubleshooting Your Library
Interpreting LEDs
Scalar i6000 User’s Guide 100
Table 16
LED On/Off Combinations
Explanation1 2 3 4 5 6
Off Off Off Off Off Off Robotics are disabled, the access door
is open, or the LBX
terminator is misaligned.
On Off Off Off Off Off The library has one control module and no expansion modules.
On Off Off On Off Off The library has one control module and one expansion module.
On Off Off On On Off The library has one control module and two expansion modules.
On Off Off On On On The library has one control module and three expansion modules.
On Off Off Off On On The library has one control module and four expansion modules.
On Off Off On Off On The library has one control module and five expansion modules.
On Off Off Off On Off The library has one control module and
six expansion modules.
On Off Off Off Off On The library has one control module and seven expansion modules.
On On Off Off Off Off The library has one control module and eight expansion modules.
On On Off On Off Off The library has one control module and nine expansion modules.
On On Off On On Off The library has one control module and ten expansion modules.
On On Off On On On The library has one control module and eleven expansion
module
s.
LBX LED Version 03
Interpreting Power
Supply LEDs 3
Power supply problems are reported in tickets. To physically identify a
power supply, note the power supply number and module number in the
ticket details. Modules can have up to two power supplies each. The top
supply is #1 and the bottom supply is #2.
The library can be physically configured to include
up to seven expansion modules. If any of the
expansion modules include drives, those modules
also will have power supplies.