120 Using the Menus
Load Firmware
Load Firmware allows you to manually update your firmware using a firmware upgrade tape cartridge.
Path:
Demo Test
Demo Test randomly moves tapes within the library to demonstrate robotic motion.
Selection Description/Result
1 Open the I/E door and inset the firmware
upgrade tape into the I/E slot.
2 From the Tools menu, highlight and
press .
Loads firmware.
3 Press and to select which firmware
you want to upgrade.
Available options are:
Drive 1: upgrades firmware for Drive 1
Drive 2: upgrades firmware for Drive 2
All Drives: ugrades both drives with a single
command
4 Press to highlight Execute ( ) and
then press .
The new firmware is loaded and the upgrade
tape is retuned to the I/E slot.
5 A confirmation message is displayed.
Press to dismiss.
6 Remove the upgrade tape from the I/E
slot.