Drive Maintenance Test
Drive Maintenance allows you to perform several different drive diagnostic tests.
To better understand these tests, you need to understand the format of the tape. The tape is divided into
four data sections. Each data section contains 96 tracks (96*4=384 tracks, the number of tracks on a
generation one cartridge). On each edge of the tape (two servo bands), and between the databands (three
servo bands), there are pre-formatted servo bands (five in total). A wrap is defined as a trip from logical BOT
to logical EOT (a round trip would be two wraps).
Each test is described in more detail below.
3 When the test is complete, a completion
message is displayed. Press to
dismiss.
If the Self Test fails, there is probably
something obstructing motion of the picker.
Open the door and pull out the magazines to
verify that all the tapes are pushed into their
slots. Look for anything that appears to be
blocking the path of the picker. Retry the test.
If it still fails, contact technical support.
Note
The drive maintenance tests are only supported for libraries with LTO drives.
Note
Run time records the test time in minutes and seconds (m:ss).
Power on self test
(POST)
Runs self diagnostics. This test takes approximately one minute.
Fast Read/Write The drive reads and writes two wraps worth of data (a trip down and back) in
each of the four data sections. Ten data patterns are used in this test. No more
than 1.5% of the tape is used. This test takes approximately 25 minutes.
Normal Read/
Write
The drive reads and writes 96 wraps worth of data (all the tracks) in each of
the four data sections. No more than 1.5% of the tape is used. Ten data
patterns are used in this test. This test takes approximately 22 minutes.
Media Read/Write Since media damage usually comes from the edges of tape to the center of
tape, the media test performs a read/write test by writing two wraps on each
of the two outside data bands, closest to the edge of tape, on both edges of
the tape, for the entire length of tape. This test takes approximately 20
minutes.
Head Read/Write In this test the drive performs a resistance check on the recording head, then
it does a read/ write test where it writes two wraps in each of the two center
data bands of tape to verify the head is performing well. This test takes
approximately 20 minutes.
Wrap This test is used to ensure that the drive is communicating correctly with the
host and the library.
Selection Description/Result